Building Lighting Protection Calculation (Excel)

1

  • Calculate Area of Building / Structure
  • Calculate Collection area of Structure
  • Calculate Probable No of Strike on Structure
  • Calculate Overall Risk Factor
  • Calculate whether Lighting Protection Required or Not
  • Calculate Number of Down Conductor

FREE DOWNLOAD

17 Responses to Building Lighting Protection Calculation (Excel)

  1. cinmoi's avatar cinmoi says:

    Thank u

  2. Rameshkumar's avatar Rameshkumar says:

    Thanks for your post. i need one clarification, as per calculation sheet, down conductors are not varying while changing the height of the building. Is height of the building considered for down conductors

  3. nethravathi nethra's avatar nethravathi nethra says:

    Hello Sir,

    My Self is Nethra, am working in Electrical consultancy field as an Design Engineer. I need some clarification regarding FRLS wire. In Residential , Apartments all are using FRLS wire , i just wanted know what is reason behind that. Is there any IS standards for that?? Plz do the need full. Am awaiting your reply.

    Warm Regards , Nethra

  4. Eswaran.G's avatar Eswaran.G says:

    Sir,
    My self is Eswaran and working in HT maintenance. I need numeric relay settings and minimum settings of relay. which one is the best among the relays.

    with regards
    eswar

  5. Sony Francis's avatar Sony Francis says:

    Thank you very much Mr. Jignesh

    Best Regards, Sony Francis Ele. Design Engr. Kuwait National Petroleum Co.

    Sent from my iPhone

    >

  6. R K Veerabhadra Rao's avatar R K Veerabhadra Rao says:

    Hello sir,

    IS 694 : 2010 is for ” POLYVINYL CHLORIDE INSULATED UNSHEATHED
    AND SHEATHED CABLES/CORDS WITH RIGID AND
    FLEXIBLE CONDUCTOR FOR RATED VOLTAGES
    UP TO AND INCLUDING 450/750 V
    ( Fourth Revision )” . It defines all wires in 2 categories FR ( Flame retardant ) & FR-LSH ( Flame retardant Low smoke and halogen) . The FRLS category is under commercially available category Between FR and FR-LHS.

  7. vengat's avatar vengat says:

    Dear sir
    i need some clarification for arc gap in between two rods of lightning arrester that could be used for a 11 kV transmission lines
    1)The space in between two metal rod will give a capacitance effect or it will act as a resistance
    2)what standards could i follow for getting accurate results for calculation of arc in between two metal rods
    3)what will be the change in the density of arc (electrical parameters) when it sparks out from leading electrode and when it reaches the end electrode after ionising the air molecules when a lightning strike occurs directly lightning strokes and if lightning hits the transmission line( please provide guidance such that it would be useful for my carrier)

  8. Rakesh Tailor's avatar Rakesh Tailor says:

    Dear Sir,

    Please mail me OHSAS practices docs or general safety required in Transmission & Distribution (rural electrification) work.

  9. Kuldeep Singh's avatar Kuldeep Singh says:

    Dear Sir

  10. Kuldeep Singh's avatar Kuldeep Singh says:

    Dear Sir,

    A building structure height is 95 meter and a vertical air termination lighting protection is provided at top. will it cover 95meter in circle at an angle of 45 degree…..

  11. Kuldeep Singh's avatar Kuldeep Singh says:

    Dear sir,

    Greeting!!!

    A building structure height is 95 meter and a vertical air termination lighting protection is provided at top. Will it cover 95 meter in circle at an angle of 45 degree..

  12. PURVESH SONI's avatar PURVESH SONI says:

    Kindly Change the heading to “Lightning”. Presently its “Lighting”

  13. ramkumar's avatar ramkumar says:

    IS 2309 has been replaced by IS IEC 62305.

  14. Rajendra's avatar Rajendra says:

    Hi
    I need help to design Lightening protection system as per IEC 62305.
    If anybody is having template / procedure to prepare design document please share.
    Rajendra

  15. Ashsih Kumar's avatar Ashsih Kumar says:

    Hello Sir,

    I need some support regarding earthing. We are working in Smart City Proejcts in which we are installing various equipments at city junctions, red lights, footpaths, divider etc.For teh same we are doing chemical earthing (with 1.2 m rod) nearby the equipment. We found equipments failure which may be due to earthing issue. Our problem is that when we measure earth resistance there its coming 60-70 ohms. It may be due to conductivity between electrodes while measuring as well as improper earthing as its surrounded/covered by concrete/bitumin etc.

    Please advise how we can ensure proper earthing either going by another method for functionality of equipment as well as acceptance by OEMs how to measure or any equivalent parameter which we can show in place of earthing resistance.

    Regards,
    Ashish Kumar