Calculate Lighting Fixture’s Beam Angle and Lumen

Example 1: Calculate Lighting Fixture’s Lumen and Diameter of Illumination at surface having following details.

  • Required illumination at surface is 1390 Lux
  • The distance from Lighting Fixture to illumination surface is 3 Meter.
  • The Fixture Beam Angle is 10 Degree.

1234

Calculation:

  • Required Lux at Surface (E2) =1390 Lux.
  • Distance between Lighting Fixture and Surface (D) = 3 Meter.
  • Fixture Beam Angle (ϕ)= 10°
  • Irradiance at 1.0 meter (E1)= DxDxE2
  • Irradiance at 1.0 meter (E1)=1390x3x3 =12510 Lumen / M2
  • Irradiance at 1.0 meter (E1)= 12510 Lumen / M2
  • Solid Angle of The Lamp (Ω) =2xπx(1-COS(ϕ/2))
  • Solid Angle of The Lamp (Ω) =2×3.14x(1-COS(10/2)) =6.28x(1-0.996)
  • Solid Angle of the Lamp (Ω) =0.0239 Steradian.
  • Required Lumen of Lighting Fixtures= E1x Ω
  • Required Lumen of Lighting Fixtures=12510×0.0239
  • Required Lumen of Lighting Fixtures=299 Lumen.
  • Illumination Diameter at surface =0.018xDx ϕ
  • Illumination Diameter at surface =0.018x3x10
  • Illumination Diameter at surface =0.54 Meter.

Example 2: Calculate Lighting Fixture’s Beam Angle and Illumination Diameter at surface having following details.

  • Required illumination at surface is 22 Lux
  • Lighting Fixture Lumen is 1547 Lumen.
  • The distance from Lighting Fixture to illumination surface is 4 Meter.

Calculation:

  • Required Lux at Surface (E2) =22 Lux.
  • Distance between Lighting Fixture and Surface (D) = 4 Meter.
  • Irradiance at 1.0 meter (E1)= DxDxE2
  • Irradiance at 1.0 meter (E1)=4x4x22 =352 Lumen / M2
  • Irradiance at 1.0 meter (E1)= 352 Lumen / M2
  • Solid Angle of The Lamp (Ω) = Lumen of Lighting Fixtures / E1
  • Solid Angle of the Lamp (Ω) =1547 / 352
  • Solid Angle of the Lamp (Ω) =4.394 Steradian.
  • Solid Angle of The Lamp (Ω) =2xπx(1-COS(ϕ/2))
  • 39 =2×3.14x(1-COS(ϕ/2))
  • Fixture Beam Angle (ϕ)=145°
  • Illumination Diameter at surface =0.018xDx ϕ
  • Illumination Diameter at surface =0.018x4x145
  • Illumination Diameter at surface =10.44 Meter.

Example 3: Calculate Lux Level and Illumination Diameter at surface having following details.

  • Lighting Fixture Lumen is 299 Lumen.
  • The distance from Lighting Fixture to illumination surface is 3 Meter.
  • The Fixture Beam Angle is 10 Degree.

Calculation:

  • Required Lux at Surface (E2) =1390 Lux.
  • Distance between Lighting Fixture and Surface (D) = 3 Meter.
  • Fixture Beam Angle (ϕ)= 10°
  • Solid Angle of The Lamp (Ω) =2xπx(1-COS(ϕ/2))
  • Solid Angle of The Lamp (Ω) =2×3.14x(1-COS(10/2)) =6.28x(1-0.996)
  • Solid Angle of the Lamp (Ω) =0.0239 Steradian.
  • Lumen of Lighting Fixtures= E1x Ω
  • 299= E1x0.0239
  • Irradiance at 1.0 meter (E1)= Lumen of Lighting Fixtures / Ω
  • Irradiance at 1.0 meter (E1)=299 / 0.0239
  • Irradiance at 1.0 meter (E1)= 12506 Lumen / M2
  • Lux at Surface (E2) = E1 / (DxD)
  • Lux at Surface (E2) =12506 / (3×3)
  • Lux at Surface (E2) =1389.5 Lux
  • Illumination Diameter at surface =0.018xDx ϕ
  • Illumination Diameter at surface =0.018x3x10
  • Illumination Diameter at surface =0.54 Meter.

12 Responses to Calculate Lighting Fixture’s Beam Angle and Lumen

  1. Vivekanand Pandey's avatar Vivekanand Pandey says:

    Thank you sir

  2. It s very useful for me
    Thank you sir

  3. Md. Mostaq's avatar Md. Mostaq says:

    Thanks for this valuable mail.

  4. HARSHAD's avatar HARSHAD says:

    Dear sir

    WE HAVE 5 KW SOLAR ROOF TOP HYBRID SYSTEM

    HOW MANY BETTRY CONNECTED WITH THIS SYSTEM AND ONE THIK IS THAT ABOUT THE BETTRY when its charged up 95% from the solar the solar power outomectic cut from the dc side and go to inverter .
    itd grid tride solar system

    sir

    please advise …

  5. AJAS ABDUL RASHEED's avatar AJAS ABDUL RASHEED says:

    excellent

  6. omprakash2063@gmail.com's avatar omprakash2063@gmail.com says:

    dear sir in street lighting same circuit if i have to use two size of cable then how to calculate voltage drop calculation

  7. This blog is waesome. really useful

  8. hi i want bus bar calculation sheet but unlock version is not available so can u send me link for that

  9. ramya's avatar ramya says:

    Dear sir, In cable sizing.how will you tell voltage drop of running and staring is limiting between 3 and 6.is these values are fixed.

  10. ARULANANDAM M's avatar ARULANANDAM M says:

    Excellent articles. Thanks for sharing.

  11. Thank you for all these nice developments but could you please explain the following formula :
    “Illumination Diameter at surface =0.018xDx ϕ”, specially concerning the 0.018 figure which rather looks like an approximation ?.
    Best regards
    Claude P

  12. jtm4890's avatar jtm4890 says:

    Why your use Distance (D) where should be Room Area?

Leave a Reply

Discover more from Electrical Notes & Articles

Subscribe now to keep reading and get access to the full archive.

Continue reading