Calculate Street Light Pole’s Distance / Fixture Watt / Lighting Area

(1) Calculate Distance between each Street Light Pole:

Example: Calculate Distance between each streetlight pole having following Details,

  • Road Details: The width of road (w) is 11.5 Foot.
  • Pole Details: The height of Pole is 26.5 Foot.
  • Luminaire of each Pole: Wattage of Luminaries is 250 Watt, Lamp Out Put (LL) is 33200 Lumen, Required Lux Level (Eh) is 5 Lux, Coefficient of Utilization Factor (Cu) is 0.18, Lamp Lumen Depreciation Factor (LLD) is 0.8, Lamp Lumen Depreciation Factor (LLD) is 0.9.
  • Space Height Ratio should be less than 3.

Calculation:

  • Spacing between each Pole=(LL*CU*LLD*LDD) / Eh*W
  • Spacing between each Pole=(33200×0.18×0.8×0.9) / (5×11.5)
  • Spacing between each Pole= 75 Foot.
  • Space Height Ratio = Distance between Pole / Road width
  • Space Height Ratio = 3. Which is less than define value.
  • Spacing between each Pole is 75 Foot.

(2) Calculate Street Light Luminaire Watt:

Example: Calculate Streetlight Watt of each Luminaire of Street Light Pole having following Details,

  • Road Details: The width of road (w) is 7 Meter. Distance between each Pole (D) is 50 Meter.
  • Required Illumination Level for Street Light (L) is 6.46 Lux per Square Meter. Luminous efficacy is 24 Lumen/Watt.
  • Maintenance Factor (mf) 0.29, Coefficient of Utilization Factor (Cu) is 0.9.

Calculation:

  • Average Lumen of Lamp (Al) = 8663 Lumen.
  • Average Lumen of Lamp (Al) =(LxWxD) / (mfxcu)
  • Average Lumen of Lamp (Al)= (6.46x7x50) / (0.29×0.9)
  • Average Lumen of Lamp (Al)=8663 Lumen.
  • Watt of Each Street Light Luminar = Average Lumen of Lamp / Luminous efficacy
  • Watt of Each Street Light Laminar = 8663 / 24
  • Watt of Each Street Light Luminaire = 361 Watt

(3) Calculate Required Power for Street Light Area:

Example: Calculate Streetlight Watt of following Street Light Area,

  • Required Illumination Level for Street Light (L) is 6 Lux per Square Meter.
  • Luminous efficacy (En) is 20 Lumen per Watt.
  • Required Street Light Area to be illuminated (A) is 1 Square Meter.

Calculation:

  • Required Streetlight Watt = (Lux per Sq.Meter X Surface Area of Street Light) / Lumen per Watt.
  • Required Streetlight Watt = (6 X 1) / 20.
  • Required Streetlight Watt = 0.3 watt per Square Meter.

46 Responses to Calculate Street Light Pole’s Distance / Fixture Watt / Lighting Area

  1. Panneer SELVAM (ETS Limited, Dubai)'s avatar Panneer SELVAM (ETS Limited, Dubai) says:

    Your sincere effort and goodwill contribution are to be thanked at all times.

    Paneer Selvam | Manager (Marketing)

    Emirates Transformer & Switchgear Limited

    Jebel Ali | Dubai | United Arab Emirates

  2. I acknowledge the hard efforts of sharing thoughts among all educators, scientists of Mr. Jignesh Parmar, see my thoughts for all educators: We all remain as students in our short life on this world?

    Helping others (students) to develop a deep love and respect for themselves, others, and their environment occurs through an open sharing of ideas and a judicious approach to discipline. When the voice of each student is heard, and environment evolves where students feel free to express themselves. Class meetings are one way to encourage such dialogue. I believe children have greater respect for their teachers, their peers, and the lessons presented when they feel safe and sure of what is expected of them. In setting fair and consistent rules initially and stating the importance of every activity, students are shown respect for their presence and time. In turn they learn to respect themselves, others, and their environment.

    • DWIGHT R. MACHICA's avatar DWIGHT R. MACHICA says:

      thanks for the knowledge shared to us and it is very useful refference on how to calculate or computation for the street light proper engineering works

  3. Prasad Jose's avatar Prasad Jose says:

    It seems so informative for the engineers especially electrical engineers for their practical knowledge improvement and of course for the timely help for urgent reference..

  4. Mariegold's avatar Mariegold says:

    very useful information. but i will like to ask, what if u were not given the illuminance, but u were given the intensity, area served and efficacy, how do u find the power, based on an operation of 12hrs per day?

  5. Tabish Hilal's avatar Tabish Hilal says:

    It is Really helped me in real time calculation.

  6. Thet's avatar Thet says:

    Thank you so much for your sharing.

  7. Juma Ganiyu's avatar Juma Ganiyu says:

    Very helpful

  8. Juma Ganiyu's avatar Juma Ganiyu says:

    I have 8m pole and the distance between one pole to the next is 50m, the width of the road is 30m. I want to find the wattage of the LED lamp that will give the max illumination. HOW DO I GET IT. Please help me..

  9. Dear sir ,i need simple calculation of indoor lighting lux design.

  10. AbduRahman Yusuf's avatar AbduRahman Yusuf says:

    When a number of Single phase loads are powered/fed through a TPN DB. How do we get/calculate the Three Phase Total Loading of the DB, especially to aid sizing of the DB’s 3-Phase Main Breaker and Feed Cable selection?

  11. Sunil's avatar Sunil says:

    Height of high mast is 16 meter, The area of ground 85000 sq meter (340 meter long and 250 meter wide). Please suggest me, how much high mast will be installed and no. of lamps with wattage and type.

  12. ONASIS's avatar ONASIS says:

    DEAR SIR,
    HOW TO CALCULATE THE UTILIZATION FACTOR AND MAINTENANCE FACTOR FOR ILLUMINATION CALCULATION

  13. Jagadeesh's avatar Jagadeesh says:

    My road width is 5Mts,Distance between poles 20Mts,height o pole is 8mts
    What LED i can use for this application

  14. Jagadeesh's avatar Jagadeesh says:

    Any post regarding LED selectio.Will be helpful

  15. Anupam Saha's avatar Anupam Saha says:

    can anybody please guide me regarding how much wattage of LED will be suficient for a 16 metre height highmast?

  16. Shiv Kumar's avatar Shiv Kumar says:

    Dear Sir ,

    when you have calculated the spacing between each pole in that case why you use same factor in two time :- Lamp Lumen Depreciation Factor (LLD) is 0.8, Lamp Lumen Depreciation Factor (LLD) is 0.9 .

    I think another one will be – Light Loss Factor

    Thanks

    Regards
    Shiv Kumar

  17. dinesh kumar's avatar dinesh kumar says:

    please let me know the distance between high mast light and residential buildings

  18. Nazari's avatar Nazari says:

    Please provide us with solar street lighting design, what is the average lux requirement for road lighting? which codes can I refer to?

  19. Gurvinder Pal Singh's avatar Gurvinder Pal Singh says:

    The width of Street is 4m.25watt led is proposed in the street.What should be the height of pole to achieve lux level as per norms in C type roads.

  20. kunal's avatar kunal says:

    i have 50 watt street light of 140 lm/watt .so please send how much area it will cover. if i will mount it at 15ft,20ft,25ft.

  21. siddharth jain's avatar siddharth jain says:

    i have godown of 136 mts lenght and 30 mtrs width. the space available for solar mounting is 50 mtrs away from the godown.i want to mount 20 watts lighting system in all 44 pillars cris cross.please suggest me what rating convertor or invertor can be used? what will be the rating of my panel in KW ,as well as battery bank requirements..what will be the witing details do please suggest me

    Siddharth jain.

  22. kulanyhai velu's avatar kulanyhai velu says:

    how to calculate lumens of the lamp(LL),wattage of luminarie=250 watt
    1 watt=50 lumens
    LL=205*50=12500 lumens
    for your calculation LL=33200 Lumens(how to calculate)

  23. eswaran's avatar eswaran says:

    dear Mr. Parmar,
    Good Day!

    Am Mr. Eswaran Ravichandran Managing director of GREEN GULF ENGINEERS. Now i have one project its very new area. I need your support for complete electrical design and street light design as per local municipality standard. I leave my mailing id here with this below mentioned box. Kindly share with your experience with us. other things we discuss via email else over telephone or skype

  24. Marifatullah's avatar Marifatullah says:

    The best information.

  25. Mogal Amjad's avatar Mogal Amjad says:

    thank you very much bro god bless

  26. Mohsin's avatar Mohsin says:

    Distance between 2Poles , Pole Heightx3.5Times (Min.) Pole Heightx4.5Times.
    Ex: For 8m Pole 28m(Min.) and 36m(Max.)

  27. kulbhushan lal seth's avatar kulbhushan lal seth says:

    under (2) calculate street light luminaire watt it is mentioned as lux per squire meter it should be lumens per squire meter. Lux means lumens per squire meter. The distance of 50 meter with 7 meter high pole seems more . Either the spacing should be less or the pole height should be more. for uniformity of lux level . you need to see the polar curve of the fitting. the value worked out seems to be just under the luminaire

  28. bob craven's avatar bob craven says:

    I have noticed that in town 30 mph limits there are steet lamps about 25 metrs apart and the poles are low ones about 5/6 meters only wheras on the main roads out of town at apeeed in excess of 30 mph but only up toi 60 mph the poles are aboiut 15 metres and give greater illumination and are spaced about 45 metres apart.

    Is there any generallity to this nationwide or does every council or the Hihways authotrity do there own thing when it come down to the lamp posts spacings.

    ie can we say that town lights are so many metres apart say between 20 and 35 metres and that urban lights are again so many metres apart. say between 40 and 50 metres.

  29. kusanale's avatar kusanale says:

    Sir, what is the standard value of space to height ratio

  30. Teja's avatar Teja says:

    Super sar and hiw to caluculate the cabel size and amps load tell ne sar

  31. Asadullah's avatar Asadullah says:

    Thank you so much for your sharing.

  32. rggarcia's avatar rggarcia says:

    Sir, in your calculation 1 ,If lamp output LL is 33200 lumen for one luminaire, why not use 2×33200 lumen since there are two luminaires for the calculation area. Please explain

  33. Shaik's avatar Shaik says:

    Good information and simply explained

  34. Peter Nena's avatar Peter Nena says:

    This website may have copied from you: http://iian.kr/wordpress/?page_id=10327

  35. Deepak Kumar Mittal's avatar Deepak Kumar Mittal says:

    very good

  36. Eduardo T. Solo Jr.'s avatar Eduardo T. Solo Jr. says:

    Good morning sir,
    Do we have a table for the required Lux Level/ required illumination level for street lights.

    Thank you sir.

    • Naresh Varshney's avatar Naresh Varshney says:

      Recommended Levels of Illumination (BIS, 1981)Table 6

      Road Characteristics Avg Illumination (Lux) Min / Avg Illumination (Lux) Type of Luminaries Preferred

      Important traffic routes carrying fast traffic 30 0.4 Cutoff

      Main roads carrying mixed traffic like city main roads/streets, arterial roads, throughways 15 0.4 Cutoff

      Secondary roads with considerable traffic like local traffic routes, shopping streets 8 0.3 Cutoff or semi-cutoff

      Secondary roads with light traffic 4 0.3 Cutoff or semi-cutoff

  37. Dhupam Rai's avatar Dhupam Rai says:

    Thank you for your effort to make us understand. I found it truely helpful

  38. Hemant Rout's avatar Hemant Rout says:

    Good Answer
    thanks for ans

  39. As per parameters defined by Ahmedabad
    Muncipal corporation width in metters Or feets
    and distance between poles 75 feets but where
    Amc goes opened new wide 60 feets roads
    For public facility and sundrikaran of city
    Highly poor / non proper reflecton of light shead on 60 feets seniour citizens are suffring
    So i Appeal Ahmedabad muncipal commistioner for restructres new two way
    Side new poles opposite jogni mata na mander
    Badreshwar koterpur new oppened
    Wide 60 feets road towards Akshardham
    Society in public intrest
    We shall wait for favourable possative
    Steps
    Nanik Ram Dodeja
    Akshardham society koierpur sardarnagar
    382475
    Ph 6354997072

    s
    Roads

  40. Naresh Varshney's avatar Naresh Varshney says:

    I think, Calculation is wrong, because there is no mention Pole height

  41. Naresh Varshney's avatar Naresh Varshney says:

    Also not using Pole Arm Angel for spreading road width

  42. SR Rao's avatar SR Rao says:

    “Required Illumination Level for Street Light (L) is 6 Lux per Square Meter.”
    my comments:
    The units are Wrong!
    Lux= Lumens/ sqm.

Leave a Reply

Discover more from Electrical Notes & Articles

Subscribe now to keep reading and get access to the full archive.

Continue reading